Nikon SIM
Why Use This Microscope?
The N-SIM structured illumination platform is a super-resolution microscope capable of approximately doubling the resolving capability of traditional fluorescence microscopy. Unlike “iterative” super-resolution techniques such as STORM and PaLM, SIM does not require stringent sample preparation or imaging buffers and can be used with most standard fluorescent proteins and/or organic dyes. Our system is outfitted to accomplish 2D- and 3D- SIM on both static and fixed samples and TIRF-SIM for live preparations. Importantly, thanks to its integration with a high-end workstation and robust GPU, the lengthy SIM reconstruction processes of the past have been dramatically revamped to enable near real-time reconstruction and visualization of the contribution of parameter modification “on-the-fly”. Such advancements have speed up the SIM imaging process nearly 12 fold.

The N-SIM structured illumination platform is a super-resolution microscope capable of approximately doubling the resolving capability of traditional fluorescence microscopy. Unlike “iterative” super-resolution techniques such as STORM and PaLM, SIM does not require stringent sample preparation or imaging buffers and can be used with most standard fluorescent proteins and/or organic dyes. Our system is outfitted to accomplish 2D- and 3D- SIM on both static and fixed samples and TIRF-SIM for live preparations. Importantly, thanks to its integration with a high-end workstation and robust GPU, the lengthy SIM reconstruction processes of the past have been dramatically revamped to enable near real-time reconstruction and visualization of the contribution of parameter modification “on-the-fly”. Such advancements have speed up the SIM imaging process nearly 12 fold.
Camera:
- Andor iXon Ultra DU-897 EMCCD monochrome camera
Imaging Modes:
- 2D SIM (multi- channel, -plane) live or fixed samples
- 3D SIM (multi- channel, -plane) live or fixed samples
- TIRF SIM (currently single channel) live samples
Excitation Specs:
- Full set of visual cubes for blue, green, and red –emitting probes.
- Diode Laser Lines and Power (measured at fiber tip):
- 405nm, 21 mW
- 488nm, 74 mW
- 561nm, 78 mW
- 647nm, 42.5 mW
Objective Lenses:
- SR Apo TIRF (oil) 100x 1.49 NA WD 0.12
Charges:
Note: To use the microscope you must have an active iLab account. Reservations are made through our on-line iLab calendar.Contact Max or Tegy to arrange training.
Location:
- MCN T-2216
| SERVICE | *RATE/UNIT |
|---|---|
| LSM 510 Confocals, scope time | $46.00 / hour |
| Confocal, scope time scope time | $49.75 / hour |
| Widefield, scope time | $46.00 / hour |
| TEM, scope time | $113.00 / hour |
| Zeiss Crossbeam, scope time | $61.99 / hour |
| Live Imaging, Extended Hours (special permissions) | $35.00 / hour |
| Nikon Spinning Disk, scope time | $35.00 / hour |
| Nikon SoRa, scope time | $35.00 / hour |
| Nikon SIM Super Resolution, scope time | $35.00 / hour |
| Nikon STORM Super Resolution, scope time | $35.00 / hour |
| Nikon TIRF, Multi-Excitation | $35.00 / hour |
| Zeiss Z.1 Lightsheet | $35.00 / hour |
| EM PROCESSING | |
| Embed (Spurr's) | $58.75 / capsule |
| Embed Durcupan | $58.75 / capsule |
| Embed SBEM | $113.00 / capsule |
| Freeze Substitution | $113.00 / capsule |
| High Pressure Freezer | $35.00 / capsule |
| Thick section | $59.74 / capsule |
| Thin section | $116.49 / capsule |
| Negative stain, material only | $6.00 / hour |
| ESEM prep, material only | $10.00 / hour |
| Sputter Coater | $10.00 / hour |
| CPD | $10.00 / hour |
| Technical Help | |
| Imaging for hire, training, protracted help | $67.00 / hour |
| Analysis Workstations | $7.00 / hour |